Radio Isotopes

Product List



Ge68/Ga68 Generator

Ge68/Ga68 Generator

What 68Ge/68Ga generator (half-life: 270 days) provides an excellent source for the positron-emitting radionuclide 68Ga. 68Ga is mainly used for...
Read More

Mon Iodine-131 Solution

Mon Iodine-131 Solution

Content Oral solution containing sodium iodide (Na131I), sodium thiosulphate and sodium carbonate-bicarbonate buffer Description MON.IYOT-131 74 – 18500 MBq oral...
Read More

Mon Iodine-131 Capsule

Mon Iodine-131 Capsule

Content Hard gelatine capsule containing sodium iodide (Na131I), disodium hydrogen phosphate, sodium thiosulphate and sodium carbonate-bicarbonate buffer Description MON.IYOT-131 0.37...
Read More

Mo99/Tc99m Generator

Mo99/Tc99m Generator

What MON.TEK 99Mo/99mTc generator contains fission Molibdenium-99 (99Mo) adsorbed by aluminum oxide (Al2O3) in a glass column. Technetium-99m (99mTc) formed by the decay of 99Mo,...
Read More


Ge68/Ga68 Generator

What

68Ge/68Ga generator (half-life: 270 days) provides an excellent source for the positron-emitting radionuclide 68Ga. 68Ga is mainly used for radiolabelling peptides which is used chiefly in nuclear medicine oncology for diagnostic applications

Calibration Activities

10, 20, 30, 40,50 mCi

Shelf Life

Generator: 270 days from the date of production
Eluate: 68minutes after elution time

Storage

Generator: At room temperature below 25 0C, in lead shield (Do not freeze)
Eluate: At room temperature below 25 0C, protected from light in lead shield

Packaging

Generator set:

  • 1 unit 68Ge/68Ga radionuclide generator
  • Patient Information Leaflet.



Mon Iodine - 131 Solution

Content

Oral solution containing sodium iodide (Na131I), sodium thiosulphate and sodium carbonate-bicarbonate buffer

Description

MON.IYOT-131 74 – 18500 MBq oral solution contains fission product radioactive iodine (131I) as an active substance which has 8.02 days half-life and used for diagnosis and treatment of thyroid diseases.

Calibration Activities

2 mCi(74 MBq), 5 mCi (185 MBq), 10 mCi (370 MBq), 15 mCi (555 MBq), 20 mCi (740 MBq), 25 mCi (925 MBq), 30 mCi (1110 MBq), 50 mCi (1850 MBq), 60 mci (2220 MBq), 75 mCi (2775 MBq), 80 mCi (2960 MBq), 100 mCi (3700 MBq), 125 mCi (4625 MBq), 150 mCi (5550 MBq), 175 mCi (6475 MBq), 200 mCi (7400 MBq), 250 mCi (9250 MBq), 300 mCi (11100 MBq), 400 mCi (14800 MBq), 500 mCi (18500 MBq)

Shelf life

30 days from the production

Storage

At room temperature below 25 0C, in lead shield

Packaging

Type I glass vial with bromobutyl rubber stopper in lead shield in a box



Mon Iodine-131 Capsule

Content

Hard gelatine capsule containing sodium iodide (Na131I), disodium hydrogen phosphate, sodium thiosulphate and sodium carbonate-bicarbonate buffer

Description

MON.IYOT-131 0.37 – 7400 MBq (10µCi -200 mCi) oral capsule contains fission product radioactive iodine (131I) as an active substance which has 8.02 days half-life and used for diagnosis and treatment of thyroid diseases.

Calibration Activities

16 µCi (0,59 MBq), 50 µCi (1,85 MBq), 100 µCi (3,7 MBq), 1 mCi (37 MBq), 2 mCi(74 MBq), 5 mCi (185 MBq), 10 mCi (370 MBq), 15 mCi (555 MBq), 20 mCi (740 MBq), 25 mCi (925 MBq), 30 mCi (1110 MBq), 50 mCi (1850 MBq), 75 mCi (2775 MBq), 100 mCi (3700 MBq), 125 mCi (4625 MBq), 150 mCi (5550 MBq), 175 mCi (6475 MBq), 200 mCi (7400 MBq)

Shelf life

30 days from the production

Storage

At room temperature below 25 0C, in lead shield

Packaging

A hard gelatine capsule in a polypropylene plastic tube within a lead shield and a polymethylmethacrylate capsule ingestion apparatus in a box



Mo99/Tc99m Generator

What

MON.TEK 99Mo/99mTc generator contains fission Molibdenium-99 (99Mo) adsorbed by aluminum oxide (Al2O3) in a glass column. Technetium-99m (99mTc) formed by the decay of 99Mo, is a radioactive isotope having a half-life of 6.007 hours. After eluting by 0.9% NaCl solution, 99mTc Sodium Pertechnetate solution which is isotonic, colorless, clear, sterile, non-pyrogenic and suitable for I.V. injection is obtained. (99mTc) Sodium Pertechnetate solution can be administrated to the patients directly as a diagnostic agent or for labeling the kits.

Calibration Activities

5, 10, 15, 20, 25, 30, 35, 40, 45, 50 GBq (Given values are for 99Mo activity on calibration date)

Shelf Life

Generator: 21 days from the date of production
Eluate: 12 hours after elution time

Storage

Generator: At room temperature below 25 0C, in lead shield (Do not freeze)
Eluate: At room temperature below 25 0C, protected from light in lead shield

Packaging

Generator set:

  • 1 unit 99Mo/99mTc radionuclide generator
  • 5 vials of 10mL and 5 vials of 5 mL sterile, non-pyrogenic 0.9% NaCl solution in the box,
  • 2 x 5 units sterile, non-pyrogenic evacuated vials in the box,
  • 10 units elution label for vial and 10 units label for lead shield,
  • 10 units of swab with alcohol of 70% isopropyl,
  • Patient Information Leaflet.